High-speed medical CT detector with low noise, stable performance, and scalable design for fast integration.
X-Tile HS
Compact. High-speed. Tileable CT detector.
One scalable detector building block for rotating and stationary medical CT — designed to simplify detector development and support flexible system integration.

Built to scale.
Engineered for speed.
X-Tile HS brings true four-side tileability, high-speed acquisition, low noise, wide dynamic range, and low power consumption into one compact standard module for medical computed tomography (CT).
Designed for rotating and static CT systems, X-Tile HS supports scalable detector configurations from 32 to 256 slices and beyond, as well as stationary multi-source CT architectures.
What are the key benefits of X-Tile HS?
Scales from 32 to 256 slices and beyond using one standard module
Enables flexible detector geometries with minimal inactive areas
Supports rapid gantry rotation and stationary multi-source CT with linear response down to 50 µs
Delivers high signal-to-noise performance, wide dynamic range, and clean projection data for low-dose medical imaging
Simplifies gantry design and cooling with a compact form factor and low thermal load
Enables accurate positioning and ASG alignment with precision mounting features
Supports flexible readout integration with customer readout electronics, X-Tile HS DAS, or a complete readout chain designed to integrate with DT’s AIDA platform

Key features
- Four-side tileable architecture with uniform pixel pitch across module boundaries
- Medical-grade, low-afterglow GOS scintillator with BSI photodiode technology
- On-module 24-bit ADC with simultaneous sampling and autoscaling full-scale range
- Configurable integration time
- Compact module with mounting and alignment features for positioning and ASG alignment
- Embedded tungsten shielding
- High-speed LVDS digital interface
- Integration with the scalable, modular AIDA readout platform
Built for advanced medical CT applications
- Diagnostic whole-body and cardiac CT
- Image-guided radiotherapy
- Compact and mobile CT
- Stationary multi-source CT
Downloads and links
One module. Multiple CT architectures.
True four-side tileability allows X-Tile HS modules to be combined in both axial (Z) and transaxial (X) directions. A uniform 1.12 mm (Z) × 1.06 mm (X) pixel pitch across module boundaries minimizes inactive areas and enables flexible detector geometries.
Configurable integration times from 50 µs to 1.6 ms support both rotating CT and the short X-ray pulses of stationary multi-source CT systems. A medical-grade GOS scintillator, BSI photodiode technology, and on-module 24-bit ADC provide a 121 dB dynamic range and high signal-to-noise performance for low-dose medical imaging.
At just 11.35 mm high, X-Tile HS makes efficient use of radial space inside rotating CT gantries. Typical power consumption of 0.65 W per tile keeps thermal load low, helping simplify detector cooling and thermal management.

Flexible readout. From detector to host.
Manufacturers with their own readout electronics can integrate X-Tile HS directly or combine it with X-Tile HS DAS.
For a complete signal path from detector to host, X-Tile HS is designed to integrate with DT’s scalable, modular AIDA platform, reducing development effort and integration risk.
Technical specifications
X-Tile HS detector

| Parameter | Value |
| Anatomical coverage at isocenter | 20 mm at standard CT geometry |
| Tileability | Four-side, Z and X directions |
| Pixel configuration | 32 x 16 / 512 pixels |
| Pixel pitch | 1.12 mm (Z) × 1.06 mm (X) |
| Dynamic range | 121 dB |
| Integration time | 50–1,600 µs |
| Electrical interface | High-speed digital LVDS |
| Typical power consumption | 0.65 W at 25 °C |
| Mechanical footprint | 35.74 × 16.86 x 11.35 mm |
X-Tile HS DAS

| Parameter | Value |
| Detector support | Up to 8 X-Tile HS modules |
| Tile matrix | 2 × 4 |
| Maximum pixel capacity | 4,096 |
| Slices | 128 per DAS; 256 with two DAS |
| Input interface | High-speed LVDS digital data |
| Output interface | DT proprietary high-speed LVDS X-Link |
| Power consumption | ~4W (with full load, detector excluded) |
| Mechanical footprint (W, L, H) | 132 × 55 × 12.5 mm |
X-Tile HS FAQ
Explore the key questions about X-Tile HS — from performance and scalability to applications and system integration.
What is X-Tile HS?
X-Tile HS is a high-speed, four-side tileable CT detector module from Detection Technology. Each X-Tile HS module combines a medical-grade GOS scintillator, a backside-illuminated (BSI) photodiode and an on-module 24-bit analog-to-digital converter in a compact 11.35 mm high module with 512 pixels (16 × 32). CT manufacturers use X-Tile HS as one standard building block for rotating and static CT detectors.
What is new in X-Tile HS compared with the original X-Tile?
X-Tile HS keeps the four-side tileable design of Detection Technology’s established X-Tile series and adds high-speed acquisition. X-Tile HS supports integration times down to 50 µs with linear response, low noise and on-module 24-bit digitization. The pixel pitch of 1.12 mm (Z) × 1.06 mm (X) is the same as in the original X-Tile.
Which CT systems is X-Tile HS designed for?
X-Tile HS is designed for medical CT systems from value-segment 32-slice scanners to high-slice clinical and cardiac CT with 64 to 256 slices and beyond, as well as for static multi-source CT. Typical applications are diagnostic whole-body and cardiac CT, image-guided radiotherapy, compact and mobile CT, and static multi-source CT.
Can X-Tile HS be used for static CT?
Yes. X-Tile HS is designed for both rotating and static CT, using the same module. In static multi-source CT, the X-ray sources are pulsed in very short exposures. X-Tile HS supports integration times down to 50 µs with linear response, so it can capture these short pulses, and its four-side tileable design supports ring and large-area detector geometries.
How many slices can be built with X-Tile HS?
CT detectors from 32 to 256 slices and beyond can be built from the same X-Tile HS module. Each module has 32 slices (pixels in Z); modules are tiled in both the axial (Z) and transaxial (X) directions. A 256-slice detector uses eight X-Tile HS modules in Z.
What coverage does X-Tile HS reach for cardiac CT?
A 256-slice X-Tile HS detector reaches 160 mm coverage at the isocenter at standard CT geometry. Each X-Tile HS module covers 20 mm at the isocenter. 160 mm coverage is the benchmark for rotating cardiac CT.
How fast is X-Tile HS?
X-Tile HS supports integration times from 50 µs to 1.6 ms, with linear response maintained down to 50 µs. This covers rapid gantry rotation in rotating CT and the short X-ray pulses of static multi-source CT.
Can X-Tile HS be used to upgrade an existing CT scanner?
Yes. X-Tile HS is suitable both for upgrading existing CT scanners and for designing new ones. Its pixel geometry remains the same as X-Tile, helping simplify upgrades by maintaining the same pixel size. Its compact 11.35 mm module height supports tight radial space inside CT gantries, and its precise mounting and alignment features and standard connector support integration into existing system designs.
What scintillator and photodiode does X-Tile HS use?
X-Tile HS uses an integrated, medical-grade, low-afterglow gadolinium oxysulfide (GOS) scintillator matched to a backside-illuminated (BSI) photodiode. The signal is digitized on the module by a 24-bit analog-to-digital converter with autoscaling full-scale range. Optical crosstalk is below 10%.
How is X-Tile HS mounted and aligned?
Each X-Tile HS module has one M3 mounting hole and two alignment pin holes for accurate positioning and anti-scatter grid alignment. The module has no electronics on its sides, which allows tiling on all four sides; the module is designed for a uniform pixel pitch across module boundaries. Embedded tungsten shielding is integrated in the module.
How can X-Tile HS be integrated into a CT system’s readout chain?
X-Tile HS is designed for three integration levels:
- Module: the X-Tile HS module with the manufacturer’s own readout electronics.
- Module and data acquisition: the X-Tile HS module with Detection Technology’s X-Tile HS DAS, connected to the manufacturer’s own data combining.
- Complete readout chain: the X-Tile HS module with Detection Technology’s data acquisition, data combiner board and the DT API software interface, designed to integrate within AIDA, Detection Technology’s modular CT detector readout platform, for a complete signal path from detector to host.
One X-Tile HS DAS reads out a 2 × 4 group of X-Tile HS modules (128 slices); a 256-slice detector uses two X-Tile HS DAS boards per two-module-wide section.
Is X-Tile HS suitable for low-dose imaging?
X-Tile HS supports low-dose imaging. Its low noise, 121 dB dynamic range and 24-bit on-module digitization support signal capture across strongly varying attenuation levels, and its low-afterglow GOS scintillator supports clean projection data.
How can I evaluate X-Tile HS?
Samples and evaluation kits of X-Tile HS are available from Detection Technology. Contact Detection Technology through www.deetee.com to discuss an evaluation.